Feed-in tariffs

Creating a new dataset

Data record: feed-in tariff

  1. Specify country

  2. (optional) Specify location

  3. (optional) Specify type of installation
    e.g. building systems

  4. Specify name
    e.g. PV-Tarif 1, EEG Mai 2017, …

  5. Specify validity period
    Beschreibt den Beginn der Förderung

  6. Specify Payout period

  7. Specify tariff limits

    Definition tariffs:
    PV generator power is given in PV*SOL® under STC conditions. The rates are calculated accordingly. The definition of generator output and tariff limits may differ due to different promotion guidelines or due to the grid operator’s own definitions.

    • Tariff zoning
      An averaged feed-in tariff is calculated for all output ranges up to the installed PV generator output. The entire PV generator output is first divided up between the individual feed-in connections or zones and then added up.

    • Graduation of tariffs
      With the graduated tariff, the feed-in tariff changes abruptly when a power limit is exceeded. This means that the feed-in tariff results directly from the installed PV output.

      Example
      Feed-in rate 1: from 0 kW ; 1 EUR/kWh
      Feed-in rate 2: from 30 kW ; 0,5 EUR/kWh
      PV generator power: 50 kWp

      Feed-in tariff paid out
      Tariff zoning: 0,8 €/kWh $ \left( \frac{30 \text{ kW}}{50 \text{ kWp}} \cdot 1 \text{ €/kWh} + \frac{20 \text{ kW}}{50 \text{ kWp}} \cdot 0,5 \text{ €/kWh} = 0,8 \text{ €/kWh} \right)$
      Tariff graduation: 0,5 €/kWh

  8. Determine rate reimbursements
    Using the button, entries can be added or deleted using the button.

    1. Feed-in compensation
      Only the directly fed PV energy is reimbursed.

      Feed-in tariff: Feed-in tariff

    2. Self-consumption
      The PV energy generated that is not directly fed into the grid is taken into account. Charging of the battery is also considered as self-consumption. When you select Delivery, the values are not taken into account as revenues, but as costs.

      Feed-in tariff: Self-consumption

    3. Basic compensation
      The total PV energy generated is taken into account.

      Feed-in tariff: Basic compensation

United Kingdom: Total Installed Capacity (TIC) oder Declared Net Capacity (DNC)

TIC is the maximum DC power at average irradiation of the best month, with a clear sky and an optimal angle of inclination.
The DNC is the TIC minus all losses up to the inverter as AC power. If these definitions are used, the tariff zones must be adjusted accordingly.


See also