The P5 system includes a buffer tank using solar and process heat plus auxiliary heating to supply a space heating loop.
P5: Process Heating Loop with Central Aux. Heating and Buffer Tank
| # | Hydraulic Connection / Components | P3 | P5 |
|---|---|---|---|
| 1 | Process heating device | x | x |
| 2 | Return mixing valve | x | x |
| 3 | DHW tank with external heat exchanger | x | |
| 4 | Heat distribution | x | x |
| 5 | External heat exchanger | x | x |
| 6 | Buffer tank bypass valve | x | x |
| 7 | Collector loop - Heat exchanger | x | x |
| 8 | Power station | x | x |
| 9 | Solar buffer tank | x | x |
| 10 | Auxiliary heating | x | |
| a | Collector loop | x | x |
| b | Collector array | x | x |
| c | Space Heating Requirement | x | |
| d | Heating Loop | x | |
| e | DHW Consumption | x |
* Collector suitable for process steam generation, for example Fresnel collector.