The A5 standard systems available differ from one another in the combination tank they use:
The tank in tank system consists of a relatively small DHW tank and a larger tank enclosing it. In the lower area, this is heated by the solar system, while the upper area is heated by the auxiliary heating.
The other type of combination tank contains an internal heat exchanger for DHW supply which runs through the entire tank. It is also heated by the solar system in the lower area and by the auxiliary heating in the upper area.
On the page System Definition (System name), tab DHW-circuit has priority over the auxiliary heating can be made.
A5 - Combination Storage System for Hot Water and Heating, with Heating Return Temperature Lift
A5.1 - Combination Storage System for Hot Water Only
A5.2 - Combination Storage System (Tank in Tank) for Hot Water and Heating, with Heating Return Temperature Lift
A5.3 - Combination Storage System (Tank in Tank) for Hot Water Only
A5.4 - Combination Storage System (Tank in Tank) for Hot Water and Heating
A5.5 - Combination Storage System for Hot Water and Heating
# | Hydraulic Connection / Components | A5 | A5.1 | A5.2 | A5.3 | A5.4 | A5.5 |
---|---|---|---|---|---|---|---|
1 | Auxiliary heating | x | x | x | x | x | x |
2 | Combination tank with internal heat exchanger | x | x | x | |||
3 | Combination tank with tank_in_tank | x | x | x | |||
4 | Stratification | x | x | ||||
Different Components | |||||||
a | Collector loop | x | x | x | x | ||
b | Collector array | x | x | x | x | ||
c | Controlled pump for the collector circuit | x | |||||
d | DHW Consumption | x | x | x | x | ||
e | Heating Loop | x | x | x | x |