Variant menu: System Definition > Tank > Electric Element

A2 or A4 system: Single coil DHW tank, used as standby tank, page Electric Element

On page Electric Element:

  1. Define whether there is an electric water heater element.
  2. Enter the electrical output either as an absolute value or related to the tank volume. The respective other value is calculated and displayed.
  3. Enter the installation height in percent of the tank height.
  4. Define the operating times of the heater element by clicking the fields for entire months or by using the magnifier for individual days.

The required values differ depending on the intended use of the tank.