Space heating

The heating requirement for the month … does not conform to the yearly profile and the climate data.
→ The heating output must match the outdoor temperatures. When necessary, correct the settings on the settings page.

Heat pump

x% of the generated energy for DHW was met by the heating element.
→ Select a heat pump with higher power.

x% of the generated energy for space heating was met by the heating element.
→ Select a heat pump with higher power.

The power of the heat pump plus heating element (x kW) is not sufficient to meet the heating load (y kW).
→ Select a heat pump with higher power.

Ground source

Drilling depth must be less than or equal to the maximum drilling depth.
→ Click the sizing button.

The total length of the probe, X m, is too long or too short by Y%.
→ Modify the parameters – within possible ranges – and then click on the sizing button until no more warning messages are shown.

The ground has cooled by x% after one year. Please check the design.
→ Reduce extraction power and/or increase heating element power.

Systems HP1 and HP2

Please select a system with a heating buffer tank.
→ Please note: if you select another system, all dependent values will be reset.

The range of the radiator heating is too large to be supplied by the heat pump.
→ Select a different heat pump or, if possible, revert to low-temperature heating.

System

x% of the energy required for domestic hot water ’ + #13#10 + ’ could not be supplied!
→ Increase the power of the heat pump (select a different heat pump) or reduce DHW requirement (less meaningful solution, as cold showers are not the intention).

x% of the space heating requirement could not be supplied!
→ Increase the power of the heat pump (select a different heat pump) or reduce the space heating requirement (less meaningful solution, as freezing is not the intention).