Das ist jetzt als *.valentin-software.co Energies and coverage shares :: GeoT*SOL® help

The (coverage) shares of the individual energies are given as percentages in relation to the respective area.

Energies

Energy generated / Year

  • Energy output from the heat pump
  • Energy output from the boiler
  • Energy output from the solar system (= delivered energy of the solar circuit minus solar storage losses)
  • Energy output from the heating element

Utilized energy / Year

  • Space heating
  • Domestic hot water

Power consumption / Year

  • Power for the heat pump or its compressor
  • Power for auxiliary energy (pumps, fans)
  • Power for a solar circuit pump
  • Fuel for a boiler in bivalent systems

Losses / Year

  • Tank losses
  • …fraction of solar tank losses
  • Circulation of the domestic hot water
  • Solar circuit piping in the house
  • Solar circuit outdoor piping

Solar loop

  • Solar fraction, energy from the solar system, based on the sum of generated energies
  • Solar fraction, domestic hot water
  • Utilization rate of the solar system
  • Irradiation on the solar collector area
  • Energy emitted by the solar collectors

Photovoltaic system

Energy / Year

  • Generated PV Energy = Generated energy of the photovoltaic system in one year
  • Of which own consumption = Generated PV energy absorbed by the electrical consumers (the electrical consumers are defined on the page System Selection)
  • Of which surplus = Generated PV Energy - own consumption
  • Self-consumption share = own consumption * 100 / Generated PV Energy

Consumption / year

  • Total electr. energy consumed = Consumption of all electrical consumers in this system
  • Of which covered by PV = Generated PV energy absorbed by the electrical consumers (the electrical consumers are defined on the page System Selection)
  • Of which purchased externally = Energy not generated by this plant (usually purchased from the local grid operator)
  • Degree of self-sufficiency = energy purchased externally / covered by PV