Das ist jetzt als *.valentin-software.co CO₂ Comparison :: GeoT*SOL® help

On the CO₂ Comparison tab, enter the emission factors (in g CO₂/kWh):

  • Heat pump system electricity

  • Heat pump system boiler
    (Only for bivalent systems: fuel of the boiler in the heat pump system, independent of the reference system.)

  • Reference system (fuel type)
    (The label shows the fuel type entered on the Cost Comparison tab.)

The values are saved with the project and in the profile. Reference values according to GModG Annex 9 (in g CO₂ equivalent/kWh):

  • Electricity (grid): 560

  • Natural gas: 240

  • Heating oil: 310

  • Liquefied petroleum gas: 270

  • Hard coal: 400

  • Lignite: 430

  • Wood: 20

Based on this data and the information on the heat pump and the auxiliary energy consumers, the following calculations are performed:
  • CO₂ emissions/year
    for each system (reference system, heat pump system, if applicable heat pump system + photovoltaics)

  • CO₂ savings compared to the reference system

  • Cumulative CO₂ emissions (chart)
    All curves are linear, since the annual emissions do not depend on price increases. The reference system is shown as a red dashed line; the legend contains the fuel type.